On 19 November 2026 ICH published the key outcomes of its Assembly meeting in Prague, held on 17 and 18 November. The first item under approved guidelines reads: "The ICH Assembly adopted ICH Q1: Stability Testing of Drug Substances and Drug Products as a final, harmonised guideline to be published on the ICH website in the coming weeks for implementation. This foundational guideline will supersede seven current guidelines: the ICH Q1A-Q1F series and ICH Q5."
The announcement says "ICH Q5". The draft text released for consultation in April 2025 is more specific: it "supersedes ICH Q1A-F and Q5C guidelines." Six Q1 documents plus Q5C would make seven, but the final text should settle the exact list, and it is worth checking when it appears. Q1A(R2), the core of the series, dates from the early years of ICH and has been cited in almost every stability section written since.
The final text is not yet public, and the regional implementation dates are not yet set. What follows is based on the Step 2 draft and the Expert Working Group's own presentation of it. The final version may differ, and the first job when it appears is to compare the two.
Scope matters too. The Step 2 draft says it applies to marketed drug products, "including those associated with registration and lifecycle/post-approval changes." It is not a blanket replacement for the phase-appropriate stability expectations that apply to clinical-stage products, where applicability should be assessed proportionately.
One guideline, organised differently
The working group was frank about the structure. In its Step 2 presentation it advised reviewers to read the draft "in its entirety," because "the organisation of this guideline is different from the existing ICH stability guidelines. Content that may initially appear to be missing may be provided in a different section."
That advice applies equally to CMC writers. Most stability sections, templates and SOPs are built around the old series: Q1A(R2) for the core design, Q1B for photostability, Q1D for bracketing and matrixing, Q1E for evaluation and extrapolation, and Q5C for biotechnological products. In the draft, those topics move into one body:
- Sections 3 to 7 cover the protocol for formal stability studies, batch selection, container closure, testing frequency and storage conditions.
- Section 8 covers photostability.
- Section 13 covers data evaluation, including shelf life and extrapolation.
- Annex 1 covers reduced designs, including bracketing and matrixing.
- Annex 2 covers stability modelling, including the old Q1E content.
- Annex 3 gives dedicated stability guidance for advanced therapy medicinal products, a product type the working group describes as new to ICH guidance.
A sentence such as "stability data were evaluated in accordance with ICH Q1E" will, in time, need a new reference. Across a portfolio that is a long list of small edits, in submissions, templates and internal procedures. It is easier to plan once than to discover one section at a time.
New content that reaches the dossier
The working group described several areas as new. Each one is likely to change what a stability section has to say.
- In-use stability (Section 11). The draft gives guidance on studies supporting the in-use period and storage conditions after opening or preparation, and on how to label them.
- Short-term storage conditions (Section 10). This is separate from in-use. It covers products whose label includes a short-term storage condition.
- Processing and holding times for intermediates (Section 9). The working group says this section "articulates when data should be included in a regulatory submission and when it may be managed within the PQS." That is a scoping decision, and it shows up in the manufacturing sections as well as stability.
- Reference materials, novel excipients and adjuvants (Section 12).
- Labelling (Section 14). Storage statements and excursions outside the labelled condition, derived from the stability studies.
- Commitments and lifecycle (Section 15), including new guidance on post-approval changes.
Several of these connect sections that are often written separately. An in-use claim appears in the stability section, in the pharmaceutical development section and in the labelling. A holding time appears in the description of the manufacturing process and in the stability data that justify it. When the evidence for one statement sits in three places, the three places need to agree. We described the same pattern for packaging in our note on FDA's container closure draft.
Modelling: the justification is the deliverable
Annex 2 combines the old Q1E content with new guidance on enhanced stability modelling. The working group noted that "enhanced stability modelling is an evolving space," and the draft allows alternative approaches throughout "when scientifically justified."
That flexibility shifts work onto the writing. A reduced protocol, a knowledge-based reduction or a model-supported shelf life is only as acceptable as the argument that accompanies it: what the model assumes, why those assumptions hold for this product, how it was checked, and what the sponsor will do if real-time data diverge. In a Module 3 section, that argument has to be stated in a form a quality assessor can follow and test. It is not enough for it to exist in a statistician's report.
A note on format
The same ICH release urged members to implement eCTD version 4.0. RAPS reported that ICH ties this to the later rollout of M4Q(R2), the revision of the Module 3 content structure. Module 3 is therefore changing in its guidance, its structure and its format over the next few years, and teams that write CMC sections from structured, traceable records will find each change easier to absorb.
What to do before the text arrives
Three things are worth doing now. First, list where your templates and SOPs for marketing applications cite Q1A to Q1F or Q5C, so that the references can be updated once regional implementation is announced. Second, find the claims in current dossiers that depend on in-use, short-term storage or holding-time data, because these are the areas with the most new text. Third, when the final guideline is published, compare it with the Step 2 draft before relying on any summary, including this one.
Asthra drafts CMC Module 3 sections from batch records, CoAs, specifications and stability data, and cites each value to the record it came from, so the same result reads the same way wherever it appears.